Radiography Testing (RT)
X-ray and gamma radiography gives a permanent image of internal weld and casting quality.
Radiography testing passes X-rays or gamma rays (Ir-192, Se-75, Co-60) through the component onto film or a digital detector. Areas with voids, porosity, slag, cracks or lack of penetration let more radiation through and appear darker on the radiograph.
RT gives a permanent record, which is why codes and buyers often specify it for pressure vessels, piping and castings. Vistra arranges RT through radiation-safety-approved partner sources with AERB-licensed radiographic operations, and our Level II interpreters review and report every film.
Applications
- Spot and full radiography of vessel and pipeline welds
- Valve and pump castings
- Nozzle and branch welds
- Digital radiography (DR / CR)
Standards & acceptance criteria
Industries that use RT
Book RT testing
Radiography (RT) – Vessel Seams
X-ray / gamma radiography of long and circ seams with Level II interpretation.
Casting Radiography – Critical Areas
RT of valve and pump castings to ASTM E446 / E186 severity levels.
Valve Casting RT / MPT Review
Review of casting radiographs and MPT of critical areas to MSS SP-54/55.
Learn RT
Our course Radiography Testing (RT) Level II with Film Interpretation (10 days) covers theory, practicals and code acceptance criteria.
Frequently asked questions
Is RT carried out at our factory?
Yes. Our technicians bring calibrated RT equipment to your shop or site anywhere in India; testing can also be done at partner laboratories.
Who performs RT for Vistra?
Technicians qualified to ASNT SNT-TC-1A / ISO 9712 Level II, with Level III review of procedures and reports.
How is RT priced?
Per shift or per man-day on site; radiography per exposure and PMI or hardness per point. See the Requirements Shop for indicative rates.
Need an inspector, NDT technician or QA/QC consultant?
Tell us the product, code, location and dates – we respond within one working day.