Eddy Current & Ferrite Testing
Tube inspection, surface crack detection and ferrite measurement for duplex and SS welds.
Eddy current testing uses electromagnetic induction to detect surface cracks, conductivity changes and wall loss in conductive materials. It is widely used to inspect heat exchanger and condenser tubes with bobbin probes.
Ferrite measurement checks the delta-ferrite content of austenitic and duplex stainless steel welds, which affects corrosion resistance and cracking. Vistra provides ECT through partner teams and ferrite testing with calibrated ferritescopes.
Applications
- Heat exchanger and condenser tubes
- Surface cracks through coatings
- Duplex and SS weld ferrite
Standards & acceptance criteria
Industries that use ECT
Book ECT testing
Heat Exchanger Tube-to-Tubesheet Inspection
Tubesheet drilling, expansion, TTS weld DPT and hydro / helium tests.
SS Pharma Equipment Inspection – DPT, PMI & Ra
Hygienic weld, surface finish, PMI and passivation checks for cGMP equipment.
Chemical Plant Equipment PMI & Lining Inspection
PMI, ferrite, lining spark test and hydrotest for chemical equipment.
Learn ECT
Our course NDT Level III Preparation (Basic & Method) (6 weekends) covers theory, practicals and code acceptance criteria.
Frequently asked questions
Is ECT carried out at our factory?
Yes. Our technicians bring calibrated ECT equipment to your shop or site anywhere in India; testing can also be done at partner laboratories.
Who performs ECT for Vistra?
Technicians qualified to ASNT SNT-TC-1A / ISO 9712 Level II, with Level III review of procedures and reports.
How is ECT priced?
Per shift or per man-day on site; radiography per exposure and PMI or hardness per point. See the Requirements Shop for indicative rates.
Need an inspector, NDT technician or QA/QC consultant?
Tell us the product, code, location and dates – we respond within one working day.